Description
Technical Parameters
1U1A0299001

The Electrofusion PE Cross is a core component used to create four-way, three-dimensional pipeline intersections.
It is manufactured from high-quality polyethylene (PE) material and features four sockets with precision-embedded resistance wires.
Controlled heating, via a dedicated electrofusion welder, enables molecular-level fusion with the pipes in all four directions, forming a permanent, monolithic connection.
The joint strength exceeds that of the pipe itself. This design makes the Electrofusion PE Cross the ideal solution for fluid division and convergence in complex systems,
such as municipal water supply, drainage, and industrial networks, ensuring long-term reliability and leak-free performance.

Product Features

 

 

High Connection Reliability

Joint strength far exceeds that of the pipe material, offering superior leak resistance.

01

High-Strength Integrated Structure

The cross-shaped design forms a uniform, robust connection point after fusion, with excellent pressure-bearing performance.

02

Exceptional Durability

It has the same corrosion and chemical resistance as PE pipes, ensuring a long service life.

03

3D Flow Division Capability

Specifically designed for complex four-way pipeline networks, enabling simultaneous fluid distribution and collection.

04

Convenient Construction

No complex operations are required; the process can be completed simply using a compatible welder.

05

 

Product Dimensions

 

 

Product Name

Specification (DN)

Weight (kg)

Outer Diameter (mm)

Wall Thickness (mm)

Height (mm)

Socket Depth (mm)

Fusion Zone Width (mm)

Electrofusion Cross

110

2.145

137

15.5

266

74

40

Electrofusion Cross

160

4.59

192

17

363

98

49

Electrofusion Cross

200

9.045

249

25

450

101

46

 

Application Range

 

 

Exhibition Centers

Connecting water supply and drainage in exhibition halls, linking restrooms and air conditioning cooling pipes.
It is used in conference centers for firefighting and cleaning water pipelines, and also in plaza areas to connect sprinkler and irrigation systems to ensure smooth operation of large events.

 

Logistics Parks

In warehouse centers, it connects firefighting and surface drainage pipelines. In sorting and distribution areas, it is used for potable water and cleaning pipelines.
In office buildings, it connects water supply/drainage and air conditioning cooling pipes, ensuring efficient logistics operation.

 

Agricultural Irrigation

Simultaneous connection of main pipelines to multiple branch pipes in large-scale irrigation systems.

 

product-900-600
product-900-600
product-900-600
product-900-600

 

Company Strength

 

 

We consider quality paramount. Every electrofusion fitting must pass a "Quality Marathon" before shipment.
This includes multiple inspections and sampling checks for resistance values, appearance integrity, dimensional tolerances, and internal structure.
We firmly believe that only products that survive this rigorous selection deserve the "Certified" label and can be delivered to you.
This stringent process ensures every product you receive is reliable and durable.

We understand that every joint impacts the safety of the entire system, so we prioritize reliability above all.
Choosing us means selecting a trustworthy global supply chain partner. Together, we are committed to building leak-proof pipeline networks for the future.

baiduimg.webp
baiduimg.webp
baiduimg.webp

 

FAQ

 

 

Q: When installing the Electrofusion PE Cross, how can I ensure all four interfaces are aligned simultaneously?

A: Before installation, preliminarily fix and support the pipes. It's advisable to first align the ends of the pipes to be connected,
then sequentially insert them into the ports of the PE Electrofusion Cross, ensuring each pipe is inserted to the marked depth line.
Using appropriate clamps for auxiliary fixation can prevent misalignment caused by pipe movement during welding.

Q: What causes "whitening" on the fitting surface after welding, and what is its impact?

A: "Whitening" is often caused by rapid temperature fluctuations during welding or inferior material with poor anti-aging properties.
To address this, use fittings with better temperature resistance, allow natural, slow cooling after welding (avoiding water quenching),
and select high-quality fittings containing antioxidants.

Q: For such a critical connection point, are there additional quality verification methods?

A: Beyond observing the welder prompts and the melt indicator pins, the most reliable verification method is conducting a strict pressure test after the entire system is installed.